High discharge pressure.
Cannot be adjusted lower.
Adjustable pressure valve not func-
tioning.
VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE
EXPOSED WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN
OCCUR. UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS.
Air Leaks Hose fitting loose.
Prolonged excessive use of air.
Decrease the amount of air usage. Your com-
pressor is not large enough for the air require-
ment.
Tighten fitting.
Compressor is not delivering
enough air.
Replace the hose.
Hole in hose.
Air leaks.
Tighten fittings.
1. Check fuse box for blown fuse and replace as
necesssary. Reset circuit breaker. Do not
use a fuse or circuit breaker with higher rating
than that specified for your particular branch
circuit.
2. Check for proper fuse. You should be using
a Quick Acting fuse.
3. Check for low voltage problem.
4. Check the extension cord.
5. Disconnect the other electrical appliances
from circuit or operate the compressor on its
own branch circuit.
Fuse blown, circuit breaker tripped.Motor will not run.
Extension cord is wrong length or
gauge.
Check the extension cord.
Loose electrical connections.
Check wiring connection inside terminal box
Faulty motor.
Have checked at a local Service Center.
TROUBLESHOOTING GUIDE
RISK OF BURSTING. DO NOT OPER-
ATE THE COMPRESSOR IF THIS PROB-
LEM EXISTS. ADJUSTABLE PRESSURE
VALVE MUST BE REPLACED.
PROBLEM CAUSE SOLUTION