10 - English
NOTE: Reverse the procedure to remove the column
extension.
Fig. 18
A
B
C
The power switch is located on the left side of the mortiser.
To turn the mortiser “ON”, press the green start button (A) Fig.
19. To stop the mortiser, push the red button (B).
IMPORTANT: When the machine is not in use, the switch
should be locked in the "OFF" position to prevent unauthorized
use,
using a padlock (A) Fig. 20 with a 3/16" diameter shackle.
STARTING AND STOPPING THE MACHINE
LOCKING SWITCH IN THE “OFF” POSITION
A
B
A
The depth stop rod (A) Fig. 21 limits the depth of the chisel.
To adjust the depth stop rod (A), loosen the lever (C) and
lower the head. When the head is at the desired location,
lower the depth stop rod (A) until it contacts the top of the
column (D) and tighten the lever (C).
ADJUSTING THE DEPTH STOP ROD
A
D
C
You can move the fence (A) Fig. 22 in or out by loosening
the lock handles (B), and rotating the fence rack handle (C).
Tighten the handles (B) after the move.
NOTE: The levers (B) are spring-loaded and can be repositioned.
Pull out on the lever and reposition it on the serrated nut
located underneath the lever.
ADJUSTING THE FENCE
A
B
C
Fig. 19
Fig. 20
Fig. 21
Fig. 22
To prevent damage to the unit, place the rack
cover over the gear. This action will prevent the cover from
being trapped between the rack and the gear.
OPERATION
OPERATIONAL CONTROLS AND ADJUSTMENTS