DeWalt D25980 Power Hammer User Manual


 
8
E N G L I S H
- Physical trauma due to inappropriate lifting and
carrying of heavy equipment.
Package contents
The package contains:
1 Pavement breaker
1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or
accessories which may have occurred during
transport.
• Take the time to thoroughly read and
understand this manual prior to operation.
Description (fi g. A1 & A2)
D25980 pavement breaker has been designed for
professional heavy duty demolition, chipping and
chasing applications in concrete, brick, stone and
other masonry materials.
Fig. A1
1 On/off switch
2 Side handle
3 Tool retainer
4 Tool holder
Optional accessories (fi g. A2)
Various types of 28 mm hex. chisels are available
as an option.
Consult your dealer for further information on the
appropriate accessories.
5 Pointed chisel
6 Cold chisel
7 Scaling tool
8 Spade chisel
9 Asphalt cutter
10 Driver ground rod
11 Shank tamper
12 Plate tamper
Soft start feature
The soft start feature allows the impact rate to build
up more slowly, thus preventing the chisel or point
from "bouncing" around on the masonry when
starting up.
Fully vibration-dampened handles
The dampers in the handles (2) absorb the
vibrations transmitted to the user. This improves
user comfort during the operation.
Active vibration control
The active vibration control neutralises rebound
vibration from the hammer mechanism. Lowering
hand and arm vibration, it allows more comfortable
use for longer periods of time and extends the life
of the unit.
Electrical safety
The electric motor has been designed for a limited
voltage range. Always check that the power supply
falls within the voltage range on the rating plate.
Your D E WALT tool is double insulated
in accordance with EN 60745; therefore
no earth wire is required.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
size is 1.5 mm
2
.
When using a cable reel, always unwind the cable
completely.
Also refer to the table below.
Conductor size (mm
2
) Cable rating (amperes) )
0.75 6
1.00 10
1.50 15
2.50 20
4.00 25
)m( htgnel elbaC )
7.5 15 25 30 45 60
oltage Amperes Cable rating (amperes
115 0 - 2.0 6 6 6 6 6 10
2.1 - 3.4 6 6 6 6 15 15
3.5 - 5.0 6 6 10 15 20 20
5.1 - 7.0 10 10 15 20 20 25
7.1 - 12.0 15 15 20 25 25 -
12.1 - 20.0 20 20 25 - - -
230 0 - 2.0 6 6 6 6 6 6
2.1 - 3.4 6 6 6 6 6 6
3.5 - 5.0 6 6 6 6 10 15
5.1 - 7.0 10 10 10 10 15 15
7.1 - 12.0 15 15 15 15 20 20
12.1 - 20.0 20 20 20 20 25 -