Echo PPT-2400 Planer User Manual


 
POWER PRUNER
OPERATOR'S MANUAL
23
AIR FILTER
Level 1.
Parts required: 90008 REPOWER FILTER KIT
1. Close choke (Cold Start Position). This prevents dirt from entering
the carburetor throat when the air filter is removed. Brush accumu-
lated dirt from the air cleaner area.
2. Remove the air cleaner cover. Clean and inspect the element for
damage. If element is fuel soaked and very dirty, replace.
3. If element can be cleaned and reused, be certain it:
-properly fits the cavity in the air cleaner cover.
-is installed with the original side out.
NOTE
Carburetor adjustment may be needed after air filter cleaning/
replacement. See Carburetor Adjustment Section.
FUEL FILTER
Level 1.
Parts Required: 90008 REPOWER FILTER KIT
WARNING DANGER
Fuel is VERY flammable. Use extreme care when mixing, storing or
handling or serious personal injury may result.
1. Use a clean rag to remove loose dirt from around fuel cap and
empty fuel tank.
2. Use the “fuel line hook” to pull the fuel line and filter from the tank.
3. Remove the filter from the line and install the new filter.