Elektra Beckum RS 4000 Air Compressor User Manual


 
8
ENGLISH
adding approx. 3-5 drops of pneu-
matic oil by hand every 15 min-
utes of operation (continuous
operation) to the air inlet.
1. Put socket on the drive.
2. Set direction of rotation with the
reversing knob:
reversing knob set to the left:
forward/driving
Reversing knob set to the right:
R = reverse/loosening
3. Adjust working pressure at the com-
pressor (see Technical Specificati-
ons for max. permissible working
pressure).
4. Connect quick coupler to the air
supply.
5. Pull trigger to start.
A
Danger!
Always disconnect from air supply
before servicing.
Repair and maintenance work other
than described in this section must
be carried out by qualified specialists
only .
Check all screwed connections for
tightness, tighten if necessary.
When the tool is not lubricated by a
service unit or line oiler, manually
add 3 - 5 drops of pneumatic oil for
every 15 minutes of operation (con-
tinuous operation) into the air inlet.
Never store the tool outdoors, in
unprotected areas or in damp locati-
ons.
Pneumatic oil 0.5 litre
Special lubricant for air tools, ser-
vice units and line oilers.
Stock-no. 090 100 8540
Line oiler R1/4" female
For fitting directly to air tools. Oil
level can always be checked
through sight glass.
Stock-no. 090 105 4584
Swivel-type air inlet
DKG 1/4"
For fitting directly to air tools. Impro-
ves tool manoeuverability.
Stock-no. 090 106 0991
Socket set 1/2"
consisting of 10 sockets
(10, 11, 12, 13, 15, 17, 19, 21, 22,
24 mm).
A
Danger!
Repairs to air tools must be carried
out by qualified specialists ONLY!
Air tools in need of repair can be send to
the service centre in your country. See
Spare Parts List for address.
Please attach a description of the fault to
the air tool.
The tool's packaging materials are
100 % recyclable.
Worn out machines and accessories
contain considerable amounts of valu-
able raw and plastic materials, which
can be recycled.
These instructions are printed on paper
produced with elemental chlorine free
bleaching process.
5. Care and Maintenance
6. Available Accessories
7. Repairs
8. Environmental Protection
9. Technical Specifications
Model RS 4000
Air consumption l/min 490
Max. permissible working pressure bar 6.2
Speed min
-1
160
Square drive " 1/2
Maximum bolt size M13
Maximum torque (forward) Nm 95
Maximum torque (reverse) Nm 95
Minimum hose size (inner) mm 13
Vibration (effective value of weighted acceleration) m/s
2
1.13
Sound power level L
WA
Sound pressure level L
PA
dB (A)
dB (A)
92.9
103.9
Dimensions:
length x width x height mm 305 x 46 x 48
Weight kg 1.2