8
Modelling lamps and fuse for 90/140V
Unit Modelling lamp Code Socket Fuse Code
Style 100BX 150W halostar 23019 E27 4AF 19035
Style 400BX 150W halostar 23019 E27 4AF 19035
Option: 150W halogen 23031 GX 6,35 4AF 19035
Option: 200W halogen 23033 GX 6,35 4AF 19035
The touch pad (14) controls the modelling lamp on/off and the proportional light.
Select the power with the touch pad (15). The modelling light output (100%) is achieved when
the power value is set to maximum.
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the
light output is proportional to the selected ash power.
For all types of Style BX compact ash units use only 250 W MAX. lamps
Modelling light for mains voltage 190/260V
Use 150W/240V halostar, code 23035 or 200W/240V halogen GX 6.35, code 23034
If the modelling lamp does not illuminate, this may be due to the following:
1. The lament is broken after long use *(replace lamp and fuse)
2. The lament is broken after shock *(replace lamp and fuse)
3. An internal component failure, *(return the unit to customer service)
* Action required:
Modelling Light
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp
300W, GX 6.35 (code 23022) for Style 100 and 400 BX units.
GX 6.35 E27