FEIN Power Tools FMM250 Cordless Sander User Manual


 
6
en
Avoid overheating the material being
sanded and the power tool.
Empty the dust collector/container in time.
Observe the material manufacturer’s work-
ing instructions.
Observe the relevant regulations in your
country for the materials being worked.
Hand/arm vibrations
While working with this power
tool, hand/arm vibrations
occur. These can lead to health impairments.
The vibration emission value
during actual use of the power
tool can differ from the declared value depend-
ing on the ways in which the tool is used.
It is necessary to identify
safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use.
The vibration emission level given in this
information sheet has been measured in
accordance with a standardised test given in
EN 60745 and may be used to compare one
tool with another. It may be used for a pre-
liminary assessment of exposure.
The declared vibration emission level repre-
sents the main applications of the tool. How-
ever if the tool is used for different applications,
with different accessories or poorly maintained,
the vibration emission may differ. This may sig-
nificantly increase the exposure level over the
total working period.
An estimation of the level of exposure to vibra-
tion should also take into account the times
when the tool is switched off or when it is run-
ning but not actually doing the job. This may
significantly reduce the exposure level over the
total working period.
Identify additional safety measures to protect
the operator from the effects of vibration such
as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Emission values for sound and vibration (Two-figure – specifications as per ISO 4871)
*These values are based on a work cycle con-
sisting of no-load and full-load operation of
the same duration.
For information on the vibration class
assigned to the application tool, please see the
enclosed data sheet 3 41 30 335 06 0.
WARNING
WARNING
WARNING
Sound emission
Measured A-weighted sound power level L
wA
(re 1 pW), in decibels: 85
Measuring uncertainty K
wA
, in decibels: 3
A-weighted emission pressure power level
measured at the workplace L
pA
(re 20 µPa), in
decibels: 74
Measuring uncertainty K
pA
, in decibels: 3
REMARK: The sum of the measured emission
value and respective measuring inaccuracy
represents the upper limit of the values that
can occur during measuring.
Wear ear protection!
Measured values determined in accordance
with the corresponding product standard.
Vibrations
Classification of FEIN
application tools accord-
ing to vibration class
Weighted
acceleration*
VC0
< 2.5 m/s
2
< 8 ft/s
2
VC1
< 5 m/s
2
< 16 ft/s
2
VC2
< 7 m/s
2
< 23 ft/s
2
VC3
< 10 m/s
2
< 33 ft/s
2
VC4
< 15 m/s
2
< 50 ft/s
2
VC5
> 15 m/s
2
> 50 ft/s
2
3 41 01 091 21 0.book Seite 6 Montag, 29. Juni 2009 8:32 08