Festool MFK 700 Router User Manual


 
8
Technical data
Power consumption 720 W
Rotational speed (no load)
10000 - 26000 rpm
Tool holder 8 mm (0.31")
optional: 6 mm (0.24")
1/4"(6.35 mm)
Max. routing tool diameter 26 mm (1")
Weight 1.9 kg (4.2 lbs)
Safety
/II
Symbols
V Volts
A Amperes
Hz Hertz
~ Alternating current
n
0
No load speed
Class II Construction
rpm Revolutions or reciprocation per
minute
Ø Diameter
Warning of general danger
Read the Operating Instructions/
Notes!
f Advice or tip
Scope of delivery
The pictures for the scope of delivery are on a
fold-out page at the beginning of the instruc-
tion manual. When reading of the manual you
can fold out this page for having always an
overview of the machine.
[1-1] MFK 700 with large surface router ta-
ble
[1-2] Side stop with guide rods and ne ad-
juster
[1-3] Extraction hood for large surface router
table with extractor connector
[1-4] Router table for edge veneer with feeler
roller and extraction hood (only in SET
scope of delivery)
Intended use
The MFK 700 EQ is designed for routing wood,
plastic and similar materials.
The user shall be responsible
and liable for damages and accidents
resulting from misuse or abuse of this
tool.
Electrical connection
The network voltage must conform to the
voltage indicated on the rating plate. A 16
A safety fuse (for 120 V) or a corresponding
protective circuit-breaker is required.
See the following gure [2] for connection and
disconnection of the power cable.
Always switch the machine
off before connecting or disconnecting
the power cable!
2
Extension cable
If an extension cable is required, it must have
a suf cient cross-section so as to prevent an
excessive drop in voltage or overheating. An
excessive drop in voltage reduces the output
and can lead to failure of the motor. The table
below shows you the correct cable diameter as
a function of the cable length for the MFK 700.
Use only U.L. and CSA listed extension cables.
Never use two extension cables together. In-
stead, use one long one.
Total Extension Cord
Lenght (feed)
25 50 100 150
Cord size (AWG) 18 16 16 14
Note:
The lower the AWG number, the stronger f
the cable.