TYPE 1 FEATURES
Indicator Light
Large white button will display Red when wall console is properly
wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON, this light is o.
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE direction will
override STB fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn the powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.
Sure-Lock™ Button
When Sure-Lock™ is ON, and the door is closed, the powerhead cannot be
activated by the wall console or a remote.
•PressandreleasetoactivateSure-Lock™(redlightgoeso).
•PressandreleasetoturnSure-Lock™OFF(redlightgoeson).
WALL BUTTON
This is a lighted wall button. Press once to move
the door.
If the button is not lighted, check:
-White wire connected to terminal “W”
-Striped wire connected to terminal “B”
Open/Close Button
Opens and closes door from inside garage.
Indicator Light
-Red indicator backlight is ON.
-When Sure-Lock™ in ON, indicator is o.
Sure-Lock™ Button
-LOCK disables controls after door is
completely closed.
-UNLOCK allows controls to work normally.
Independent Light Control Button
Controls door opener lights from inside
garage.
TYPE 2 FEATURES
Indicator Light
Large white button will display Red when wall console is properly
wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON, this light is o.
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE direction will
override STB fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn the powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.
Sure-Lock™ Button
When Sure-Lock™ is ON, and the door is closed, the powerhead cannot be
activated by the wall console or a remote.
•SlideswitchuptoactivateSure-Lock™(redlightgoeso).
•SlideswitchdowntoturnSure-Lock™OFF(redlightgoeson).
TYPE 1 TYPE 2
WARNING
!
Use of any other wall control can cause unexpected
operation of the door and loss of lighting feature. Locate
wall console within sight of door but far enough from
door to prevent contacting it while operating the console.
Control must be at least 5 feet above the oor to prevent
small children from operating it.
AVERTISSEMENT
!
l’utilisation d’une autre commande murale pourrait des résultats
in attendus de la porte ainsi que le dysfonctionnement de
l’éclairage. Localisez la console murale en vue de la porte et
susamment loin de la porte pour éviter tout contact pendant
l’utilisation de la console. La commande doit être à une hauteur
minimale de 1,5 m au-dessus du sol an que les jeunes enfants ne
puissent pas l’attiendre.