Graco 16H829 Paint Sprayer User Manual


 
Starting a New Job (or Refilling the Cup)
3A1698F 13
Starting a New Job
(or Refilling the Cup)
1. Engage trigger lock and put prime/pressure relief valve
UP to release pressure.
2. Install material cup liner, fill with material, and
thread onto sprayer.
3. To prime pump, disengage trigger lock and trigger
sprayer for 10 seconds. Then release trigger and
put prime/relief valve DOWN to spray position.
4. Reverse spray tip to UNCLOG position and spray
into waste area for five seconds.
5. Put prime/pressure relief valve UP to release pres-
sure. Then rotate tip back to spray position.
NOTE: Failure to perform this operation could result
in poor spray pattern.
NOTE: If sprayer fails to prime, follow Alternate
Priming Method (page 23).
Reversible Tip Selection Chart
When spraying flammable or combustible materials:
Remove entire sprayer from hazardous location
when refilling.
Always ground the material cup when refilling.
Keep material containers covered between cup
refills.
ti14999a
ti14994a
ti16699a
ti16700a
ti15474a
ti16715a
ti15418a
ti15425a
ti14995a
ti16698a
ti16701a
ti16716a
Fine Finish Materials and Tip Sizes
Fan
Width
THIN
Stains
MEDIUM
Lacquers, Clears
HEAVY
Enamels
4 in.
(10 cm)
208 210
6 in.
(15 cm)
308 310 312
8 in.
(20 cm)
410 412
Use with all fine finish materials including “hot” solvents.
ti14991a
ti14985a
ti15491a
ti14991a
ti16713a
ti16700a
ti16992a