Graco 16W431 Paint Sprayer User Manual


 
2 312830G
Pressure Relief Procedure
Follow this Pressure Relief Procedure
whenever instructed to relieve pressure,
stop spraying, check or service equipment,
or install or clean spray tip.
1. Turn OFF power and turn sprayer pressure control to low-
est pressure setting.
2. Hold gun against side of flushing pail. Trigger gun into pail
to relieve pressure.
If you suspect spray tip or hose is clogged or that pressure has
not been fully relieved after following the steps above, VERY
SLOWLY loosen tip guard retaining nut or hose end coupling
to relieve pressure gradually, then loosen completely. Clear
hose or tip obstruction.
Gun Trigger Lock
To prevent injury when the gun is not in use, always
set the gun’s trigger lock if unit is being shut down
or left unattended.
Setup
Make sure sprayer is turned off and unplugged from power
source. Refer to your sprayer instruction manual for priming
and spray instructions.
Connect Gun to Sprayer
1. Attach supply hose to sprayer fluid outlet.
2. Attach other end of supply hose to gun swivel (5). Use two
wrenches (one on the swivel (5) and one on the hose), to
tighten all connections securely.
3. Refer to sprayer instruction manual for priming
instructions.
Installing Tip (26) and Guard (25) on Gun
1.If equipment has recently been operated,
relieve pressure. Set trigger lock.
2.Using a pencil or similar object, insert seal
(24) into back of guard (25).
3. Install guard (25) over end of gun (1).
4. Insert tip (26) in guard (25). Tighten retaining nut.
Operation
Spraying
1. Unlock trigger lock.
2. Be sure the arrow shaped tip (26) faces forward (spray).
3. Hold gun perpendicular and approximately 12-inches
(30 cm) from surface. Move gun first, then pull gun trigger
(3) to spray a test pattern.
4. Slowly increase pump pressure until coverage is uniform
and even (see sprayer instruction manual for additional
information).
Aligning Spray
1.Relieve pressure. Set trigger lock.
2. Loosen guard
retaining nut.
3. Align guard (25)
horizontally to
spray a horizontal
pattern.
4. Align guard (25)
vertically to spray
a vertical pattern.
Clearing Clogs
1. Relieve pressure. Set trigger lock.
2. Rotate tip (26) 180°. Unlock trigger lock. Trigger gun into
pail or onto ground to remove clog.
3. Set trigger lock. Rotate tip (26) 180° back to spray
position.
Cleanup
Flush gun after each work shift and store in a dry location. Do
not leave the gun or any parts in water or cleaning solvents.
WARNING
WARNING
WARNING
Trigger Locked
(no spray)
Trigger Unlocked
(spray)
ti11309a
ti11308a
WARNING
WARNING
WARNING
(4) Vertical
(3) Horizontal
ti11564a ti11563a