Installation
308612J 3
Installation
Accessories are available from Graco. Be sure all
accessories are properly sized to withstand the pres-
sures in the system.
Mount Valve
Mount the valve on a 0.50 in. (12.7 mm) diameter rod on
a mounting fixture or a dispensing machine. The bead
gun has a clamping set screw for mounting.
Connect the Air Lines
Clean all lines and connections of dirt, burrs, etc. and
blow them out with clean air before connecting them to
the system. Install an air filter in the air supply line to
remove harmful dirt and moisture from the compressed
air.
Connect Material Line
Grounding
Proper grounding is essential to maintaining a safe sys-
tem.
To reduce the risk of static sparking, ground the pump,
bead spray gun, paint spray gun and all other system
equipment.
1. Pump: Use a ground wire and clamp.
2. Air compressors and hydraulic power supplies:
Follow manufacturer’s recommendations.
3. Air and fluid hoses connected to the pump: Use
only grounded hoses with a maximum of 500 feet
(150 m) combined hose length to ensure grounding
continuity.
4. Dispensing valve: Obtain grounding through con-
nection to a properly grounded fluid hose, frame,
and pump.
5. Fluid supply container: According to local code.
6. All solvent pails used when flushing: Ground
according to local code. Use only metal pails, which
are conductive. Do not place the pail on a non con-
ductive surface, such as paper or cardboard, which
interrupts the grounding continuity.
ti16199b
ti16198b
ti16177b
Single-Acting Gun
Double-Acting Gun
ti16200b