Graco 24C293 Sander User Manual


 
7308609
Installation
Return Tube Kit 238884 (Accessory)
Return Tube Kit 238884 is available as an accessory.
The kit must be ordered separately. Refer to the sheet
packed with the kit for installation instructions.
Air Requirements
For continuous use, the 3/4 HP (550 W) agitator air
motor typically requires 3 to 4 cfm (0.09 to 0.12
m3/min) air supply.
Air Line Accessories
Attach a quick disconnect air line fitting and coupler, or
attach a ball valve for main air shut–off to the air line.
To order the 1/8” npt(m) air line fitting, order Part No.
169969. To order the coupler, order Part No. 208536.
Install an air line filter to remove harmful dirt and
moisture from the air supply. To order an air line filter,
order Part. No. 106148 (3.8” npt, 20–micron element, 5
oz. Bowl, without gauge).
CAUTION
Not lubricating the air motor will cause air motor failure.
Downstream from the filter, install an air line lubricator
for automatic air motor lubrication. Set the lubricator
feed rate at 1 drop of oil per minute for high speed or
continuous duty usage. Do not overfeed oil or exhaust
air may become contaminated. To manually lubricate
the air motor, see Lubricating the Air Motor on page
10. To order a 3/8” npt air line lubricator, order Part No.
214847.