Graco 24C522 Sander User Manual


 
4 308609
Installation
WARNING
FIRE AND EXPLOSION HAZARD
Always maintain a minimum of 1 in. clearanc
e
between rotating agitator parts and container
to prevent sparks from contact.
air line lubricator
agitator motor
air line filter
air regulator
and gauge
mix tank
(reference only)
Typical Installation
NOTE: Reference numbers and letters in parentheses
refer to the callouts in the figures and in the Parts
Drawings.
Grounding
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, the mounting
cover and all electrically conductive objects or devices
in the dispensing area must be properly grounded.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
To ground the agitator, connect one end of the
ground wire (A) to the ground connector (B) on the
agitator. See Fig.1. Connect the other end of the
ground wire to a true earth ground.
For an additional ground wire and clamp, order
Part No. 237569.
A
Fig. 1
B
Assembling and Positioning the Agitator
With an Elevator
Mount the drum cover as described in manual 306287.
The elevator must be in the down position when you
do any work on the elevator, agitator, or drum cover
assembly. Do not go under the elevator when it is
raised. Proceed to step 1 in With or Without an
Elevator.
Without an Elevator
If your system does not have an elevator, you should
install the Handles Kit to facilitate handling the drum
cover and agitator. Two people are needed to safely lift
and move the drum cover and agitator. To order the
Handles Kit, order Part No. 237524.
Place two standard 55 U.S. gallon (45 Imperial gallon)
barrels 14 in. (approximately 36 cm) apart, and center
the drum cover on the barrels with the Graco logo
centered and facing you, as shown in Fig. 2. Proceed
to step 1 in With or Without an Elevator.
Fig. 2
05734
Assembling and Positioning
Agitator Without an Elevator
14 in. (36 cm)