Clean-up (Non-Power Flush)
3A1292C 7
Clean-up (Non-Power Flush)
This procedure is for water-based and
oil-based (mineral spirit-type) paints and
coatings only.
System is pressurized. Failure to properly depressur-
ize system will result in material discharging from hose
and possible injury.
Always turn off and slowly remove air compressor from
lid assembly to depressurize system before removing:
• Hose set from sprayer
• Hose set from lid
• Lid from reservoir
1. Turn off and slowly remove air compressor from lid
assembly.
2. Remove lid assembly. Remove and clean out suc-
tion tube and strainer.
3. Rinse out reservoir or discard liner.
4. Fill reservoir with cleaning fluid and reattach lid with
suction tube and strainer.
5. Remove drain hose from reservoir lid and aim it into
a waste container.
6. With the prime/relief valve in the up position,
squeeze trigger and cycle fluid from suction hose
(T) through drain hose (R) and into a waste con-
tainer.
7. Put the prime/relief valve in the down position.
Spray into waste area with tip in reverse position
until water comes out clear. Put the prime/relief
valve in the up position.
8. Remove sprayer battery or unplug sprayer. Remove
tip assembly from sprayer and rinse. Re-install tip
assembly into sprayer.
CAUTION
ti16510a
ti16527a
ti16524a
ti16525a
NOTICE
If the drain hose is not thoroughly cleaned it can
become plugged due to paint buildup. If this does
occur, replace hose set.
ti17159a
ti16526a
R
T
Waste
ti17827a
ti17822a