Graco 257096 Paint Sprayer User Manual


 
2 313347E
Component Identification
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever
instructed to relieve pressure, stop spraying, check or
service equipment, or install or clean spray tip.
1. Turn OFF power and turn sprayer pressure control to
lowest pressure setting.
2. Hold gun against side of grounded metal flushing
pail. Trigger gun into pail to relieve pressure.
If you suspect spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
Trigger Lock
To prevent injury when gun is not in use, always set gun
trigger lock (A) if sprayer is turned off or left unattended.
Setup
Make sure sprayer is turned off and unplugged from
power source. Refer to your sprayer instruction manual
for priming and spray instructions.
Connect Gun to Sprayer
1. Attach air hose.
NOTE:
The first time you set
up the gun for spraying you
will have to cut the black air
hose to length desired.
2. Attach fluid hose.
3. See Setup instructions in
sprayer operation manual
(313316).
ID Component ID Component
A
Trigger lock
E
Air on/off valve
B
Spray Tip
F
Air hose connection
C
Safety RAC guard
G
Air adjustment valve
D
Trigger
H
Fluid hose connection
H
G
F
D
B
C
E
A
ti12849a
WARNING
WARNING
(A)
(B)
ti10352a
ti10353a
ti13318a
ti13317a