307614 9
Installation/Operation
How to Flush the Gun
WARNING
To reduce the risk of serious bodily
injury, including splashing fluid in the
eyes or on the skin, or static electric
discharge when flushing:
D Be sure the entire system, including flushing
pails, are properly grounded.
D Remove the tip guard and spray tip.
D Maintain metal to metal contact between the
gun and the flushing pail.
D Use the lowest possible pressure.
Always flush the pump and the gun before the fluid
being sprayed can dry in it.
NOTE: If it is available, the flushing procedure
provided in your pump or sprayer manual should be
used instead of this procedure.
1. Follow Pressure Relief Procedure on page 5.
2. Remove the tip guard and spray tip. Soak and
clean the parts.
3. Put the pump intake in a grounded pail of water or
solvent.
4. Start the pump at its lowest pressure.
5. Trigger the gun into the original pail. When solvent
appears, release the trigger.
6. Now trigger the gun into the solvent pail. Circulate
the fluid until the system is thoroughly flushed.
7. Follow Pressure Relief Procedure on page 5.