Graco 332158 Paint Sprayer User Manual


 
Pressure Relief Procedure
332156B 7
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Set pump valve OFF.
2. Turn engine OFF.
3. Loosen Lock Ring. Turn pressure control to lowest
setting. Trigger gun into pail to relieve pressure.
4. Rotate handle counter-clockwise to open prime
valve.
Grounding
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
ti7108a
or
ti20967a
OFF
ON
START
OFF
ON
ti5261a
ti7111b
ti7120b
ti21061a
Ground sprayer with grounding clamp to earth ground.