Setup
334466A 17
8. Make certain ON/OFF switch is OFF.
9. Plug power supply cord into a properly
grounded electrical outlet.
10. Turn prime valve down.
11. Place fluid intake with drain tube in
grounded metal pail partially filled with
flushing fluid. See Grounding, page 12.
12. Turn pressure control to lowest setting.
13. Turn ON/OFF switch to ON position.
14. Increase pressure 1/2 turn to start motor.
Allow fluid to flush through sprayer for
one minute.
ti24586a
ti24651a
ti24608a
NOTE: New sprayers are shipped with
storage fluid that must be flushed out
with mineral spirits prior to using the
sprayer.
Check flushing fluid for compatibility
with material that is to be sprayed. A
secondary flush with a compatible fluid
may be necessary. Water for latex
paint or mineral spirits for oil-based
paint.
ti24640a