Graco 390 Classic Model 24U105 Paint Sprayer User Manual


 
Cleanup
16 332758A
Cleanup
1. Relieve Pressure, page 10.
2. Remove guard and Spray Tip. For additional infor-
mation, see separate gun manual.
3. Remove siphon tube set from paint. Wipe excess
paint off outside of tubes.
4. Place siphon tube in flushing fluid. Use water for
water base paint and mineral spirits for oil base
paint. Place drain tube in waste pail.
5. Turn prime valve horizontal.
6. Hold gun against paint pail. Disengage trigger lock.
Trigger gun and increase pressure until the pump
runs steady and flushing fluid appears.
7. Stop triggering gun. Move gun to waste pail, hold
gun against pail, trigger gun to thoroughly flush sys-
tem.
8. While continuing to trigger gun, turn prime valve
down. Then, release gun trigger. Allow flushing fluid
to circulate until fluid coming out of drain tube is
clear.
ti2769a
TIA
Flush
Waste
ti2756b
ti22221a
Paint
1/4 Turn
ti22223a
ti2599ab
ti22220a