Fast Flush (ProContractor and IronMan models only)
332916C 17
Fast Flush
(ProContractor and IronMan models only)
To flush the hose and gun at an accelerated speed, per-
form the following steps:
1. Perform steps 1 - 3 of Cleanup, page 22.
2. Squeeze gun trigger and turn prime valve down to
DRAIN position and then over to FAST FLUSH.
3. Continue flushing system until fluid appears clear.
WatchDog
™
Protection System
(ProContractor and IronMan models only)
Pump stops automatically when material pail is empty.
To Activate:
1. Perform Startup.
2. Turn WatchDog switch ON and WD ON displays.
EMPTY displays/flashes and pump stops when
Watchdog protection system detects an empty
material pail.
3. Turn WatchDog switch OFF. Add material or rep-
rime sprayer. Turn pump switch OFF and ON to
reset WatchDog protection system. Turn WatchDog
switch back ON to continue to monitor material
level.
ti22940a
ti22938a
ti22033a
ti22939a