Graco ti15036b Paint Sprayer User Manual


 
Troubleshooting
3A0157B 19
Sprayer Will Not Run
(See following page for steps)
Remove control box cover. Turn
sprayer ON. Observe control
board status light on control board
(see page 13).
No light
Once Normal operation
Light on
Continuously
Control board
commanding
motor to run
Flashing See Error Code
section for further
troubleshooting
Connect a test
transducer to the
board. Does the
motor run?
Replace
potentiometer.
Pressure switch.
See Step 3. Is the
proper reading
present through the
thermal switch
wires?.
Replace the
ON/OFF switch.
See step 4. Does
the motor run?
See Step 1. Do
you have over
100 AC volts (200
for 220V units)?
See Step 2. Do
you have over
100 AC volts?
Repair or
replace
power cord.
If motor is hot, let cool and
retest. If Step 4 still shows
incorrect resistance, replace
motor. The motor has
a defective thermal device.
Replace the
transducer
Replace the
control board.
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO