Graco Inc. 288048 Paint Sprayer User Manual


 
Installation
311053E 5
Installation
Ventilate Spray Booth
Configure Gun and Manifold
(Order manifold separately. See Accessories, page
26.)
Manifolds 241161 and 241162
The gun is supplied with an internal fluid plug (4). See
FIG. 1. To use the gun in a circulating system, remove
the internal plug. In a non-circulating system, leave the
plug in place to minimize flush time.
Circulating System
1. Apply anti-seize lubricant 222955 to the threads and
mating faces of the manifold (102) and the elbows
(107), supplied unassembled.
2. Install the elbows (107) in both fluid ports of the
manifold (102).
3. Connect the fluid supply line to one elbow and the
fluid return line to the other. The manifold fluid ports
are reversible.
Non-circulating System:
1. Apply anti-seize lubricant 222955 to the threads and
mating faces of manifold (102), plug (109), and
elbow (107), supplied unassembled.
2. Install an elbow (107) in one fluid port of the mani-
fold (102), and a plug (109) in the other port.
3. Install the internal plug (4) in the gun fluid port on
the same side as the manifold plug.
4. Connect the fluid supply line to the manifold elbow
(107). See FIG.1.
5. Install the gun on the manifold, using the four
screws (14). Start the threads of all four screws, and
tighten the front two screws first, and then tighten
the back two screws to 65 in-lb (7.3 N•m).
Check and follow all National, State, and Local
codes regarding air exhaust velocity requirements.
Check and follow all local safety and fire codes.
FIG. 1: Non-Circulating Setup (Cutaway View)
TI8587b
1
Remove when used in circulating systems.
1
Replace with an elbow (107) when used in circulating
systems.
2
2
102
107
109
4
6
5