Technical Data
12 312388K
Technical Data
* Produces 10 psi (0.07 MPa, 0.7 bar) spraying pressure at aircap.
** All readings were taken with the fan valve fully open (fan full size) at the assumed operator
position. Sound power measured per ISO 9614-2.
Maximum air inlet pressure . . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Gravity Feed:
Maximum HVLP inbound air pressure . . . . . . . . . . .
Pressure Feed:
Maximum HVLP inbound air pressure . . . . . . . . . . .
29 psi (0.2 MPa, 2 bar)*
24 psi (0.17 MPa, 1.7 bar)*
Air consumption
Mini HVLP Gravity. . . . . . . . . . . . . . . . . . . . . . . . . . .
Conventional Gravity. . . . . . . . . . . . . . . . . . . . . . . . .
HVLP Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HVLP Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conventional Pressure . . . . . . . . . . . . . . . . . . . . . . .
7.0 SCFM at 29 psi (0.2 MPa, 2.0 bar)
9.5 SCFM at 43 psi (0.3 MPa, 3.0 bar)
9.5 SCFM at 29 psi (0.2 MPa, 2.0 bar)
11.8 SCFM at 24 psi (0.17 MPa, 1.7 bar)
11.0 SCFM at 50 psi (0.34 MPa, 3.4 bar)
Fluid and air operating temperature range . . . . . . . . . . . 32-109°F (0-43° C)
Spray Gun
Air inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid inlet (pressure feed) . . . . . . . . . . . . . . . . . . . . .
Mini HVLP Gravity weight with cup . . . . . . . . . . . . . .
Gravity Feed weight with cup . . . . . . . . . . . . . . . . . .
Pressure Feed weight . . . . . . . . . . . . . . . . . . . . . . . .
1/4 npsm (R1/4-19)
3/8-18 npsm (R3/8-19)
0.9 lb (0.4 kg)
1.1 lb (0.5 kg)
0.8 lb (0.37 kg)
Wetted parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum, stainless steel, engineered
plastic
Noise data**
Mini HVLP Gravity Feed
sound pressure at 29 psi (0.2 MPa, 2.0 bar) . . .
sound power at 29 psi (0.2 MPa, 2.0 bar) . . . . .
Conventional Gravity Feed
sound pressure at 43 psi (0.3 MPa, 3.0 bar) . . .
sound power at 43 psi (0.3 MPa, 3.0 bar) . . . . .
HVLP Gravity Feed
sound pressure at 29 psi (0.2 MPa, 2.0 bar) . . .
sound power at 29 psi (0.2 MPa, 2.0 bar) . . . . .
Conventional Pressure Feed
sound pressure at 50 psi (0.34 MPa, 3.4 bar) . .
sound power at 50 psi (0.34 MPa, 3.4 bar) . . . .
HVLP Pressure Feed
sound pressure at 24 psi (0.17 MPa, 1.7 bar) . .
sound power at 24 psi (0.17 MPa, 1.7 bar) . . . .
78.17 dB(A)
85.32 dB(A)
81.91 dB(A)
89.23 dB(A)
80.60 dB(A)
87.74 dB(A)
83.49 dB(A)
90.70 dB(A)
81.96 dB(A)
88.88 dB(A)
Gravity Cup Size
Mini HVLP Gravity. . . . . . . . . . . . . . . . . . . . . . . . . . .
Conventional/HVLP Gravity . . . . . . . . . . . . . . . . . . .
4 oz (125 cc)
20 oz (600 cc)