Graco Inc. 308-084 Paint Sprayer User Manual


 
308-08427
MANIFOLD SERVICE NOTES
0434
0434
Press
fit
This end 8.5-8.9”
(215-225 mm) from
manifold surface when
properly assembled
Standard o-ring is V
iton.
Optional EPR o-ring is
provided with the man
-
ifold
for compatibility with
ketone
solvents.
Must be
clean
Press fit
T
ighten until
hex bottoms
against manifold
Left-hand
threads
T
orque to
25 in-lb
(2.8 N
Sm)
T
orque to
25 in-lb
(2.8 N
Sm)
Lubricate
T
orque to
25 in-lb
(2.8 N
Sm)
Apply low strength
(purple)
Loctite
or equivalent
Apply low strength
(purple)
Loctite or
equivalent
Concave side
toward manifold
Lubricate