Graco Inc. 309523D Paint Sprayer User Manual


 
Grounding
309523D 5
Grounding
Check your local electrical code and pump/sprayer man-
ual for detailed grounding instructions.
Spray gun:
ground through connection to a
grounded fluid hose and pump/sprayer.
Fluid hose:
use only grounded hoses.
Fluid supply container:
follow local code.
Object being sprayed:
follow local code.
Gun Trigger Safety
WARNING
Read warnings, page 3.
Solvent flushing pails:
follow local code. Use only
conductive metal pails placed on a grounded surface.
Do not place pail on a nonconductive surface, such
as paper or cardboard, which interrupts grounding
continuity.
To maintain grounding continuity when flushing
or relieving pressure:
hold metal part of gun firmly
to side of grounded metal pail, then trigger gun.
Ti1102 1
WARNING
Read warnings, page 3.
Wallet-sized warning card with important injection
treatment information is included with the gun.
Additional cards are available at no charge. Pro-
vide a card to all operators.
To engage trigger lock:
turn it to position A. If engaged,
gun will not trigger. Engage trigger lock whenever you
stop spraying to avoid accidental triggering.
To disengage trigger lock:
turn it to position B.
A
Ti1950A
B
Ti1949A