Installation
313255F 11
Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
1. Pump: See F
IG. 2. Verify that the ground screw (GS)
is attached and tightened securely to the air motor.
Connect the other end of the ground wire (R) to a
true earth ground.
2. Pump fluid hoses: use only electrically conductive
fluid hoses Check electrical resistance of hoses. If
total resistance to ground exceeds 25 megohms,
replace hose immediately.
3. Viscon HP Heater: refer to the heater manual,
supplied.
4. Air compressor: follow manufacturer's recommen-
dations.
5. Spray gun: ground through connection to a properly
grounded fluid hose and pump.
6. Fluid supply container: follow your local code.
7. Object being sprayed: follow your local code.
8. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the pail
on a nonconductive surface, such as paper or card-
board, which interrupts the grounding continuity.
9. To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail, then
trigger the gun.
Setup
Wall Mount Electrical Connections. Follow all
directions and requirements in the Viscon HP Heater
manual 309524.
Cart Mount Hazardous Location Wiring. The heater is
shipped with a fitting that is suitable for wiring in
hazardous locations. Follow all directions and
requirements in the Viscon HP Heater manual 309524.
Do not use the supplied electrical cord, which is
suitable only for non-hazardous location wiring.
Cart Mount Non-Hazardous Location Wiring. See
F
IG. 3. Replace installed fitting with bushing (80),
shipped loose. Attach strain relief bushing (79). Follow
all directions in the Viscon HP Heater manual 309524 to
connect the 120V supplied electrical cord (78), or
user-supplied cord for 240V applications.
FIG. 2. Ground screw and wire
R
GS
ti12914a
The Viscon HP Heater must be installed by a quali-
fied electrician in compliance with all state and local
codes and regulations.
F
IG. 3. Non-Hazardous Location Electrical Cord
79
80
ti13261a
78
(120V only)