Graco Inc. TI4660C Paint Sprayer User Manual


 
Installation
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
MM 311071
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
www.graco.com
Printed in USA 311071A
5/2005
Installation
* Includes mix chamber and cleanout tool.
Extended wear life for abrasive materials.
When used with mix chamber AR5252 at 1000 psi
(7.0 MPa, 70 bar).
1. Remove the existing air cap (round or flat) from the
Fusion Gun and replace it with the adapter (1).
Thread the adapter onto the mix chamber until it
bottoms out.
2. Insert the packing (2) through the center of the
adapter (1) with the stepped end facing the mix
chamber.
3. Place the stud wall tip (4) onto the packing (2) and
tighten the air cap (3) with light hand force.
4. Adjust the tip orientation with a standard 5/16 in. nut
driver (provided with gun). See F
IG. 2.
Cleaning Tips
1. If the pattern begins to shrink or becomes distorted,
relieve pressure (see your gun manual) and clean
the internal dome of the tip (4) with the tip cleanout
tool (15D234). See F
IG. 3.
2. Clean out the inside diameter of the packing (2) and
the flat mix chamber with a 0.94 in. (3/32 in, 2.39
mm) dia. drill bit (Graco cleanout tool kit 246624).
3. Add a thin layer of lubricant on the outside faces of
the air cap (3) to ease cleaning.
This kit will not work with round mix chambers
(i.e. ARXXXX). If there is a round mix cham-
ber in the gun, replace it with a flat mix cham-
ber. Smaller flat mix chambers can be
ordered for lower fluid flow applications. See
Flat Mix Chamber Kit chart.
Flat Mix
Chamber Kit*
Type Flow Rate (approx.) at
1000 psi (7.0 MPa, 70 bar)
AF5252 Standard 15 lb/min (6.81 kg/min)
AF0052† Special 15 lb/min (6.81 kg/min)
AF4242 Standard 11 lb/min (4.99 kg/min)
AF0042† Special 11 lb/min (4.99 kg/min)
AF2929 Standard 7 lb/min (3.18 kg/min)
A FTM979 Stud Wall Tip is included in this kit.
NOTE: FTM762 Stud Wall Tip is available for
lower fluid flow applications as an accessory.
FTM979
Stud Wall Tip
FTM762
Stud Wall Tip
Pattern size 22 in. (559 mm) 14 in. (355.6 mm)
Spray distance 2 ft. (0.61 m) 2 ft. (0.61 m)
Fluid flow‡
15 lb/min
(6.81 kg/min)
13 lb/min
(5.90 kg/min)
The small plastic o-ring on the end of the flat
mix chamber must be removed.
Overtightening may distort the packing inside the
mix chamber. Reopen the hole with the 0.94 in.
(3/32 in, 2.39 mm) drill bit provided if necessary.
F
IG. 2
F
IG. 3
End for Air
Purge Tips
Wall Tips
End for Stud
TI3867A
TI4244A