SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The motor for your machine may draw the follow-
ing amps at maximum load.
G0596 at 110V Single-Phase ............... 14 Amps
G0597 at 220V Single-Phase .............. 8.5 Amps
G0598 at 220V Single-Phase ............... 12 Amps
G0599 at 220V 3-Phase ....................... 10 Amps
Circuit Requirements
We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit breaker size given below. Never replace a
circuit breaker with one of higher amperage with
-
out consulting a qualified electrician to ensure
compliance with wiring codes
. If you are unsure
about the wiring codes in your area or you
plan to connect your machine to a shared cir
-
cuit, you may create a fire hazard—consult a
qualified electrician to reduce this risk.
G0596 at 110V ................
15 Amp Circuit Breaker
G0597 at 220V ...............
15 Amp Circuit Breaker
G0598 at 220V ...............
15 Amp Circuit Breaker
G0599 at 220V 3-Phase .
15 Amp Circuit Breaker
Figure 1. NEMA 6-15 plug and receptacle.
Figure 2. NEMA 15-15R plug and receptacle.
Plug Type
With the exception of the G0596, the cord set
enclosed does not have a plug as the style of plug
you require will depend upon the type of service
you currently have or plan to install. We recom
-
mend using the following plugs for your machine
on a dedicated circuit only (see Figures
1–3 for
examples):
G0597 at 220V ......................... NEMA 6-15 Plug
G0598 at 220V ......................... NEMA 6-15 Plug
G0599 at 220V 3-Phase .. NEMA 15-15R Plug or
..220V Locking Shut-Off Switch (recommended)