Grizzly Model Saw User Manual


 
G1023S Series Heavy-Duty 10'' Table Saw -9-
220V Operation
Figure 7. NEMA L6-20 220V plug and outlet
Model G1023S Only:
The Model G1023S motor is wired to operate at
220V. When operating at 220V, use a NEMA-
style L6-20 plug and outlet. See Figure 7. Check
the electrical codes in your area for specifics on
wiring requirements.
Under normal 220V use, the motor draws approx-
imately 18 amps. Use a 20 amp circuit breaker or
a 20 amp slow-blow fuse. The circuit you use
should be dedicated, (i.e., the Model G1023S
should provide the only draw from that circuit). If
frequent circuit failures occur when using this
machine, contact our Service Department or your
local electrical contractor.
Because of the high amperage draw of this
machine, standard household circuit wiring may
not be of a large enough gauge. A qualified elec-
trician must install a new circuit with wires capa-
ble of handling a 18 amperage draw. Do not
attempt to modify an existing circuit by replacing
the circuit breaker with one rated for a higher
amperage.