Grizzly Model G1022proz Saw User Manual


 
G1022 Series Table Saws -9-
SECTION 3: CIRCUIT REQUIREMENTS
110V Operation
The Models SM, Z & ZF motors are prewired to
operate at 110V. See Figure 5 for a typical 110V
plug and outlet.
Models SM & Z:
Under normal 110V use, the Models SM & Z
motors draw approximately 16 amps. Use a 20
amp circuit breaker or a 20 amp slow-blow fuse.
Model ZF:
Under normal 110V use, the Model ZF motor
draws approximately 17 amps. Use a 20 amp cir-
cuit breaker or a 20 amp slow-blow fuse.
If the machine is not wired correctly a fire
could result. Make sure your wiring, recep-
tacle, plug, and circuit breaker can handle
the current draw of the machine. If you are
not sure that your electrical circuit can han-
dle the current draw, get a qualified electri-
cian to test your electrical system and do
any required upgrades. Do not attempt to
modify an existing circuit by only replacing
the circuit breaker with one rated for a high-
er amperage draw than the wiring, recepta-
cle, and plug are rated for.
The circuit you use should be dedicated, (i.e., the
machine should provide the only draw from that
circuit). If frequent circuit failures occur when
using this machine, contact our Service
Department or your local electrical contractor.
Figure 5. Typical 110V 3-prong plug and outlet.