Electrical Data
For additional capacity sizes and options, please contact the factory at 800-537-7775
Model
Power
Supply
Compressor
Air Defrost/
Beacon II
Electric Defrost - Low
Amps
Electric Defrost - High
Amps
Model RLA LRA MCA MOPD
Defrost
Heater
Amps*
Evap.
Fan
Amps MCA MOPD
Defrost
Heater
Amps*
Evap.
Fan
Amps MCA MOPD
SRN0400H2C 208-230/3/60 NRB2-0400 19.6 141.0 24.4 40 20 (1) 6 30.4 50 40 (1) 12 50.0 50
SRN0400H2D 460/3/60 NRB2-0400 10.1 62.5 15.0 20 10 (1) 3 20.0 25 20 (1) 6 25.0 25
SRN0400H2E 575/3/60 NRB2-0400 8.3 53.4 15.0 15 8 (1) 3 15.0 20 16 (1) 5 20.0 20
SRN0499H2C 208-230/3/60 2DC3R53KE 20.0 120.0 25.0 45 20 (1) 6 31.0 50 40 (1) 12 50.0 50
SRN0499H2D 460/3/60 2DC3R53KE 9.4 60.0 15.0 20 10 (1) 3 15.0 20 20 (1) 6 25.0 25
SRN0499H2E 575/3/60 2DC3R53KE 6.9 49.0 15.0 15 8 (1) 3 15.0 15 16 (1) 5 20.0 20
SRN0500H2C 208-230/3/60 2DD3R63KE 20.0 120.0 25.0 40 20 (1) 6 31.0 50 40 (1) 12 50.0 50
SRN0500H2D 460/3/60 2DD3R63KE 9.4 60.0 15.0 20 10 (1) 3 15.0 20 20 (1) 6 25.0 25
SRN0500H2E
575/3/60 2DD3R63KE 7.1 49.0 15.0 15 8 (1) 3 15.0 15 16 (1) 5 20.0 20
SRN0500M6C 208-230/3/60 2DC3R53KE 20.0 120.0 25.0 45 20 (1) 6 31.0 50 40 (1) 12 50.0 50
SRN0500M6D 460/3/60 2DC3R53KE 9.4 60.0 15.0 20 10 (1) 3 15.0 20 20 (1) 6 25.0 25
SRN0500M6E 575/3/60 2DC3R53KE 6.9 49.0 15.0 15 8 (1) 3 15.0 15 16 (1) 5 20.0 20
SRN0750H2C 208-230/3/60 2DL3R78KE 28.3 169.0 35.4 60 40 (1) 12 50.0 70 70 (2) 16 87.5 90
SRN0750H2D 460/3/60 2DL3R78KE 12.4 85.0 20.0 25 20 (1) 6 25.0 30 40 (1) 12 50.0 50
SRN0750H2E 575/3/60 2DL3R78KE 11.9 67.0 15.0 25 16 (1) 5 20.0 30 32 (1) 10 40.0 40
SRN0760H2C 208-230/3/60 2DA3R89KE 28.7 169.0 35.9 60 40 (1) 12 50.0 70 70 (2) 16 87.5 90
SRN0760H2D 460/3/60 2DA3R89KE 12.6 85.0 20.0 25 20 (1) 6 25.0 30 40 (1) 12 50.0 50
SRN0760H2E 575/3/60 2DA3R89KE 11.9 67.0 15.0 25 16 (1) 5 20.0 30 32 (1) 10 40.0 40
SRN0761H2C 208-230/3/60 3DA3R10ME 36.8 215.0 46.0 80 40 (1) 12 58.0 90 70 (2) 16 87.5 90
SRN0761H2D
460/3/60 3DA3R10ME 17.9 106.0 22.4 40 20 (1) 6 28.4 45 40 (1) 12 50.0 50
SRN0761H2E
575/3/60 3DA3R10ME 14.7 84.0 20.0 30 16 (1) 5 23.4 35 32 (1) 10 40.0 40
SRN1000H2C 208-230/3/60 3DB3R12ME 39.1 215.0 48.9 80 40 (1) 12 60.9 90 70 (2) 16 87.5 100
SRN1000H2D
460/3/60 3DB3R12ME 17.9 106.0 22.4 40 20 (1) 6 28.4 45 40 (1) 12 50.0 50
SRN1000H2E
575/3/60 3DB3R12ME 14.8 84.0 20.0 30 16 (1) 5 23.5 35 32 (1) 10 40.0 40
SRN1500H2C 208-230/3/60
3DS3R17ME 53.5 275.0 66.9 110 70 (2) 16 87.5 125 96 (2) 25 120.0 125
SRN1500H2D 460/3/60 3DS3R17ME 26.0 138.0 32.5 50 40 (1) 12 50.0 70 70 (2) 16 87.5 90
SRN1500H2E
575/3/60 3DS3R17ME 21.2 110.0 26.4 45 32 (1) 10 40.0 50 56 (2) 12 70.0 70
SRN2000H2C 208-230/3/60
4DA3R18ME 52.7 308.0 65.9 110 70 (2) 16 87.5 125 96 (2) 25 120.0 125
SRN2000H2D 460/3/60 4DA3R18ME 26.3 154.0 32.9 50 40 (1) 12 50.0 70 70 (2) 16 87.5 90
SRN2000H2E
575/3/60 4DA3R18ME 21.3 135.0 26.7 45 32 (1) 10 40.0 50 56 (2) 12 70.0 70
SRN Model - High & Medium Temperature
*Number of defrost heater contactors in parentheses
RLA - Rated Load Amps MCA - Minimum Circuit Ampacity
LRA - Locked Rotor Amps MOPD - Maximum Overcurrent Protection Device