Heath Zenith 4162 Work Light User Manual


 
2
595-5530-13
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 1, 5,
or 10 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
* If you get confused while switching modes,
turn the power off for one minute, then back
on. After the calibration time the control will
be in the AUTO mode.
INSTALLATION
For best performance, mount the fixture about
6 feet (1.8 m) above the ground.
WARNING: Turn power off at circuit
breaker or fuse.
1. Remove two nuts.
3. Tighten screws
finger tight.
2. Remove
Mounting Plate.
This fixture comes with a universal mounting
bracket. It is pre-assembled on the fixture to
fit the majority of junction box applications.
However, if the slots on the mounting plate
do not line up with the junction box screw
holes:
1. Remove the fixture mounting screws from
the mounting plate. Note: Do not remove
the ground screw.
2. Attach ground wire “pigtail” to ground
screw on mounting plate (See Recom-
mended Grounding Method for additional
information).
3. Flip the mounting plate over.
4. Attach mounting
plate to junction box.
Wire Path
Ground Screw