Heath Zenith 52-4473-6 Work Light User Manual


 
5
598-1286-01
TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light switch.
Note: Sensor has a 1
1
/
2
minute warm up period before
it will detect motion. When first turned on wait 1
1
/
2
minutes.
2. Set:
ON-TIME switch to TEST
SENSITIVITY dial to Midway
3.
Walk through the coverage area noting where you are
when the lights turn on. In TEST mode, light will stay
on for 5 seconds after sensing motion and then turn
off.
4. Adjust the SENSITIVITY to increase or decrease
the range as needed. Too much sensitivity may cause
false triggering due to heat sources in the coverage
area (see
Adjustment of Coverage Area or Troubleshooting
section).
5. Set the amount of ON-TIME you want the light to stay
on after motion is detected (1, 5, or 10 minutes).
Maximum Range Maximum
Coverage Angle*
(Top View)
FINAL ASSEMBLY
1. Push the wires into the junction box. Make sure none
of the wires get pinched.
2.
Slide the fixture assembly onto the mounting screws.
Tighten decorative nuts removed in step 1 of Installation
section securely against fixture base.
Junction Box
Mounting Screw
Decorative Nut
3. Install one medium base light bulb (100 Watt maxi-
mum).
4. Place top cover onto fixture and attach using the two
decorative nuts (included). Hand tighten only.
5. After completing the tests on page 5, caulk around
fixture base with silicone weather sealant.
Top Cover
Decorative Nut
Light Bulb (100
Watt Maximum)
Fixture Assembly
Caulk Around
Fixture Base
TEST 1 5 10
MINUTE
+
SEN
30 ft.
(9.1 m)
6 ft.
(1.8 m)
180°