598-1159-06
Bulb Installation and Relamping
When relamping, turn power off and let the fixture
cool.
Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.
To insert the new bulb, push the bulb into the right
socket so the bulb fits completely into the left
socket.
Check that the bulb is seated properly.
❒ Close the glass cover. Replace screw.
Remove the existing light fixture.
Strip about 5/8" insulation from the existing junction
box wiring.
Route the light control’s wires through the large
hole in the gasket.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mount the Light Control
Align the light control cover plate and cover plate
gasket and the junction box. Insert and tighten the
mounting screws.
If not installed on a weatherproof box or if an adaptor
plate is used, caulk the wall plate and mounting
surface with silicone weather sealant.
The halogen light must be
mounted horizontally (+/- 4°).
RIGHT WRONG
Wire the Light Control
White to White
Black to Black
Connect any fixture ground wire(s) and the cover
plate ground screw to the junction box ground
wire.
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
WARNING: Turn power off at circuit breaker
or fuse.