Heath Zenith UT-5403-BZ Work Light User Manual


 
3598-1299-01
SPECIFICATIONS
Electrical Load ............Up to 300 Watt Maximum
Incandescent [Up to 150 Watt
maximum each bulb holder.]
Power Requirements ..120 VAC, 60 Hz
Operating Modes ........Dusk to Dawn
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Monitor light control to verify that the lights come on
at night and turn off during the day.
Adjust bulb holders as needed.
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come on. 1. Light switch is turned off.
2. Floodlight is loose or burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a
new installation.
1. Turn light switch on.
2. Check floodlight and replace if
burned out.
3. Replace fuse or turn circuit breaker
on.
4. Recheck after dark.
5. Verify wiring is correct.
Lights stay on continuously. Light control is mounted in a dark
location.
Relocate light control to an area that
receives more light.
Lights flash on and off. 1. Light may be leaking through the
floodlamp reflectors.
2. Light control may be sensing shad-
ows.
1. Replace the bulbs with new high
quality PAR 38 bulbs.
2. Relocate light control to an area
away from shadows.