Hitachi DS 18DMR Drill User Manual


 
English
17
1. Insert the plug of battery charger into the receptacle.
When the plug of battery charger has been inserted into
the receptacle, the charge status lamp will blink in red.
(At 1-second intervals)
WARNING:
Do not use the electrical cord if
damaged. Have it repaired
immediately.
2. Insert the battery to the battery charger.
Insert the battery into the battery charger as shown in Fig. 6. Make sure it contacts the
bottom of the battery charger.
3. Charging
When the battery is connected to the battery charger, charging starts, and the charge
time lamp lights red, orange, or green according to the remaining charging time. (See
Table 4)
(1) Lamp indications
This charger is equipped with a charge time lamp that indicates remaining charging
time, and a charge status lamp that indicates battery status as shown in Table 4.
(a) Charging time
After charging commences, the charge time lamp lights red indicating 30 minutes,
orange indicating 20 minutes, and green indicating 5 minutes until completion.
When the battery is fully charged, the charge status lamp lights green, and the
buzzer sounds continuously for 6 seconds.
(b) Overheat standby
When the battery is overheated, it cannot be charged, and the charge time lamp
flashes red (in 0.6 second intervals). Leave the battery inserted in the charger, and
charging will commence when the battery cools down.
(c) Charging impossible
When there is a malfunction with the battery or charger, the charge status lamp
flashes orange rapidly (in 0.2 second intervals), and the buzzer sounds intermittently
for 5 seconds.
Fig. 6
Battery
Charge
Status Lamp
<UC24YJ>
Charge Time
Lamp