6-3. Auxiliary Power Panel Ratings
Unless otherwise stated, the rating of duplex outlets is the combined load of all
receptacles.
NOTE
Total power from generator NOT to exceed 3500 Watts (60 Hz)
Receptacle
Protected
By
Panel
495 218
(USA)
Panel
495 315
(USA)
Panel
495 298
(USA)
Panel
495 279
(Canada-
CSA)
Panel
495 253
(S. Africa)
Panel
495 288
(South
America)
Panel
495 289
(Australia)
Panel
495 290
(Europe)
Panel
495 283
(S.E. Asia)
60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz
240 V
Twist Lock
CB1,2
30A/
3600W
240 V
Duplex
CB1,2
15A/
3500W
See
Note 2
15A/
3500W
240 V
Duplex
CB3,4
15A/
3500W
230 V
Single
CB1
15A/
3500W
15A/
3500W
15A/
3500W
230 V
Single
CB2
15A/
3500W
15A/
3500W
15A/
3500W
230 V
Single
CB1,2
15A/
3500W
230 V
Single
CB3,4
15A/
3500W
120 V
Twist Lock
CB1
30A/
3500W
30A/
3500W
120 V
Duplex
CB1,2
CB1,3
30A/
3500W
120 V
Duplex
CB2
20A/
2400W
120 V
Duplex
CB3
20A/
2400W
20A/
2400W
See
Note 3
20A/
2400W
120 V
Duplex
CB4
20A/
2400W
See
Note 3
20A/
2400W
Total
Power NOT
to exceed
3500W 3500W 3500W 3500W 3500W 3500W 3500W 3500W 3500W
For example, for the 495 218 Auxiliary Power Panel,
120V, 1500W heater 1500W
120V, 10A chain saw 1200W
120V, 500W halogen lamp 500W
Total 3200W This loading is OK.
120V, 1500W heater 1500W
120V, 10A chain saw 1200W
120V, 5A router 600W
120V, 500W halogen lamp 500W
Total 3800W This loading is not OK.
It exceeds 3500W.
Notes: 1. Each receptacle of the duplex can provide 15A/1800W. Do not parallel the two 120V duplex receptacles.
2. Do not parallel the two 120V circuits.
3. Do not parallel the two duplex outlets.
Calculating total power provided by generator.
(See Section 10 – Auxiliary Power Guidelines)
Each receptacle can provide the watts or amps as shown
above. However, the total power can not exceed 3500W.
The rating plate on electrical apparatus will contain the watts
consumed or the rated input amps. Watts may be calculated by
multiplying the rated voltage by the rated input amps.
watts = volts x amps