Hobart 3225DX Welding System User Manual


 
OM-130 098 Page 23
6-2. Optional Auxiliary Power Receptacles
Ref. ST-188 449 / ST-174 408
Y If unit does not have GFCI re-
ceptacles, use GFCI-pro-
tected extension cord.
. Auxiliary power is not affected
by weld output.
If a circuit breaker continues to
open, contact Factory Autho-
rized Service Agent.
GFCI Receptacle Option
1 120 V 15 A AC GFCI
Receptacle GFCI1
Auxiliary power output and circuit
breaker protection is the same as
standard receptacles (see Section
6-1).
If a ground fault is detected, GFCI
Reset button pops out and
receptacle does not work. Check
for faulty tools plugged in
receptacle. Press button to reset.
. At least once a month, run en-
gine at weld/power speed and
press test button to verify GFCI
is working properly.
Australian, British, And South
African Receptacle Options
2 240 V 10 A AC Australian Re-
ceptacle RC1
3 240 Volt 13 A AC South
African Receptacle RC1
4 240 Volt 13 A AC British
Receptacle RC1
RC1 supplies 60 Hz single-phase
power at weld/power speed. Maxi-
mum output from receptacle is 3
kVA/kW.
5 Circuit Breaker CB1
CB1 protects RC1 from overload. If
CB1 opens, RC1 does not work.
Press button to reset breaker.
5
1
2
5
3
5
4