Caution
Caution: dirt sensitive area
Touching the product or parts thereof with one's
bare hands increases the desorption rate.
Always wear clean, lint-free gloves and use
clean tools when working in this area.
Vent the vacuum system and disassemble the small flange
connection. Place the protective lid.
Protective lid
Seal with
centering ring
Clamp
ISO-KF
connection flange
Further information
Refer to the Operating manual with regard to maintenance,
repair, and spare parts.
The Operating manual sina60e1
· can be downloaded from our website or
· ordered at INFICON.
Returning the product
WARNING
Caution: forwarding contaminated products
Contaminated products (e.g. radioactive, toxic,
caustic or microbiological hazard) can be detri-
mental to health and environment.
Products returned to INFICON should preferably
be free of harmful substances. Adhere to the for-
warding regulations of all involved countries and
forwarding companies and enclose a duly com-
pleted declaration of contamination.
Products that are not clearly declared as "free of harmful
substances" are decontaminated at the expense of the
customer.
Products not accompanied by a duly completed declaration of
contamination are returned to the sender at his own expense.
Disposal
DANGER
Caution: contaminated parts
Contaminated parts can be detrimental to health
and environment.
Before beginning to work, find out whether any
parts are contaminated. Adhere to the relevant
regulations and take the necessary precautions
when handling contaminated parts.
Separating the components
After disassembling the product, separate its components
according to the following criteria:
· Contaminated components
Contaminated components (radioactive, toxic, caustic, or
biological hazard etc.) must be decontaminated in accor-
dance with the relevant national regulations, separated
according to their materials, and disposed of.
· Other components
Such components must be separated according to their
materials and recycled.
Declaration of Contamination
Legally binding declaration:
We hereby declare that the information on this form is
complete and accurate and that we will assume any further
costs that may arise. The contaminated product will be dis-
patched in accordance with the applicable regulations.
Organization/company
Address
Post code, place
Phone Fax
Email
Name
Company stamp
Copies: Original for addressee
1 copy for accompanying documents
1 copy for file of sender
Operating fluid(s) used
(Must be drained before shipping.)
The service, repair, and/or disposal of vacuum equipment and com-
ponents will only be carried out if a correctly completed declaration
has been submitted. Non-completion will result in delay.
This declaration may only be completed (in block letters) and signed
by authorized and qualified staff.
Reason for return
Description of product
Type
Part number
Serial number
no
q
yes
q
Used in copper process
Seal product in plastic
bag and mark it with a
corresponding label.
This form can be downloaded from our website.
The product is free
of any substances
which are damaging
to health.
yes
q
Process related contamination of product:
toxic no
q
1) yes
q
corrosive no
q
1) yes
q
biological hazard no
q
yes
q
2)
explosive no
q
yes
q
2)
radioactive no
q
yes
q
2)
other harmful substances no
q
1) yes
q
1) or not containing any
amount of hazardous
residues that exceed the
permissible exposure limits
2) Products thus
contaminated
will not be
accepted with-
out written
evidence of
decontami -
nation.
Precautions associated with
substance
Action if human
contact
Trade/product name
manufacturer
Chemical name
(or symbol)
Harmful substances, gases and/or
by-products
Please list all substances, gases, and by-products
which the product may have come into contact with:
Manufacturer's Declaration
as defined by the Directive relating to machinery 98/37/EC,
Appendix IIb
We, INFICON, hereby declare that putting the incomplete
equipment mentioned below into operation is not permitted
until evidence is given that the system into which that incom-
plete equipment shall be installed is in accordance with the
provisions of the EC Directive relating to machinery.
We also declare that the equipment mentioned below
complies with the provisions of the Directive relating to
electrical equipment designed for use within certain voltage
limits 73/23/EEC and the Directive relating to electromagnetic
compatibility 89/336/EEC.
Angle valve
pneumatically actuated
bellows sealed
with position indicator and pilot valve
normally open
VAP016 … 040-A/X
Part numbers
250-206 250-226 250-246
250-216 250-236 250-256
Standards
Harmonized and international/national standards and
specifications:
· EN 292-2
· DIN EN 60 204-1
· ISO 9803
· ISO 1609
· ISO 4414
· DIN 28 403
· DIN 28 404
· DIN 2501-1
· DIN 24 558
Signatures
INFICON AG, Balzers
22 October 2002 22 October 2002
Remo Klaiber
Product Marketing
Management
Dr. Georg Sele
Technical Support Manager
Quality Representative
LI–9496 Balzers
Liechtenstein
Tel +423 / 388 3111
Fax +423 / 388 3700
reach.liechtenstein@inficon.com