APPLICATIONS
For charging the HITACHI batteries types EB7, EB9, EB12, EB14 series.
CHARGING METHOD
NOTE: Before plugging into the receptacle, make sure the following points.
The power source voltage is stated on the nameplate.
The cord is not damaged.
WARNING: Do not charge at voltage higher than indicated on the nameplate.
If charged at voltage higher than indicated on the nameplate, the
charger will burn up.
1. Insert the plug of battery charger into
the receptacle.
When the plug of battery charger has
been inserted into the receptacle, pilot lamp
will blink in red. (At 1-second intervals)
WARNING:
Do not use the electrical
cord if damaged. Have it
repaired immediately.
EB1212S
EB1214L
EB1220BL
EB12S
EB12B
EB912S
EB9S
EB914
EB9B
Fig. 2
2. Insert the battery to the battery charger.
Insert the battery into the battery charger as shown in Fig. 2. Make sure it contacts the
bottom of the battery charger.
SPECIFICATIONS
EB1412S
EB1414
EB14B
EB712S
EB7S
Input power source Single phase: AC120V 60Hz
Approx. 30 minutes .......... EB712S, EB7S, EB912S, EB9S, EB914,
Charging time
EB1212S, EB12S, EB1214L, EB1412S,
EB1414
Approx. 50 minutes .......... EB9B, EB12B, EB1220BL, EB14B
Charger
Charging voltage .............................. DC 7.2–24V
Charging current .............................. DC 2.5A