8.0 GENERAL INFORMATION
8.2 INSTALLATION DRAWING − N250/300H TWO STAGE
KEY
A 4” NPT Air discharge (Female)
B Electrical inlet −
Ø75mm (3”)
C 0.50“ NPT (Female)
Note: Pipe condensate drain lines separately to an
open drain due to differences in drain pressures. Use drain
lines at least as large as the connection. Read operations
manual and check local regulations
D Cooling airflow
E Exhaust airflow
F Cabinet cooling airflow
G 4 x Ø 14.2mm (0,6”)
Compressor should be bolted to the floor with
four M12 (0.5”) bolts using holes shown. Seal
base to floor with cork or rubber.
H INTELLISYS Controller
U Right
V Bottom
W Front
X Left view
Y Rear view
Z Plan view