Kompernass KH 4098 Work Light User Manual


 
Description of the appliance
q
Colour discs
w
Power plug
e
Power cable
r
Transformer
t
Connecting plug
y
Coupling nut
u
Cable
i
Underwater lamp
o
Lamp cover
a
Outer race
Commissioning
Assembly
1. Insert the connecting plug
t
into the
transformer
r
.
2. Slide the coupling nut
y
onto the
connecting plug
t
and screw it tight.
Placing the coloured disc
1. Lay the slot of the coloured disc
q
on
one of the two securing hooks of the
underwater lamp
i
.
2. Carefully press the coloured disc
q
down on the opposite side until it
audibly engages.
3. If you wish to exchange the coloured
disc
q
, lightly press a securing hook
outwards and at the same time press
the coloured disc to the side.
Placing the underwater lamps
Ensure that a mains power socket is in
the close vicinity.
Place the underwater lamps
i
as desi-
red.
The underwater lamps
i
can be opera-
ted both in and out of water.
Align the underwater lamps
i
with
the assistance of the 5-stage pivoting
device.
Insert the power plug
w
into a wall
power socket.
In permanent installations we recommend
that the transformer
r
is fastened down
with the fixing holes.
Changing bulbs
1. Turn the outer race
a
of the underwa-
ter lamp
i
in the direction of the
arrow (anti-clockwise).
You can now remove the outer race
a
.
2. Remove the transparent lamp cover-
ing
o
.
3. Pull the halogen lamp, complete with
the housing, upwards.
4. Holding the housing firmly, carefully
pull the halogen lamp, complete with
reflector, out of the housing.
5. Insert the new halogen lamp into the
housing and then press both of them
back down again.
NOTE: Ensure that the sealing ring is
not displaced.
6. Lay the lamp cover
o
onto the under-
water lamp
i
.
7. Place the outer race
a
on the under-
water lamp
i
such that the tenons fit
into the rebates of the outer race
a
.
Turn the outer race
a
in a clockwise
direction until tight.
Safety instructions
ƽ Danger of injury
Connect the appliance only to correctly
installed mains power sockets with a
supply voltage of 230 V~ at 50 Hz.
In the event of operational malfunction
and for cleaning, always remove the
power plug from the wall socket.
Always remove the power cable from
the socket by pulling on the plug, not
on the power cable itself.
Do not crease or crimp the power
cable and lay it in such a way as to
prevent anyone from stepping on or
tripping over it.
Should the power cable or the appliance
become damaged, you must have them
repaired by qualified specialists before
using them again.
Always keep the appliance beyond
the reach of children.Do not allow
children to use it.
The appliance may not be operated
in or next to swimming pools. Risk of
injury!
ƽ Attention
Always remove the plug from the wall
socket before removing the halogen
lamps.
Allow the halogen lamps to cool down
before removing them.
The halogen lamps will become very hot.
There is a danger of being burnt!
Do not use extension cables!
The maximum submersing depth for
the underwater lamps amounts to 0,5m.
Do not submerse them any deeper.
The appliance would be irreparably
damaged.
Take steps to ensure that the transfor-
mer cannot fall into the pond or water
container. The appliance would be
irreparably damaged.
The flexible power cable of the trans-
former cannot be exchanged. Should
the power cable be damaged, the
transformer must be exchanged as a
complete unit.
In exterior areas only use power
sockets of the protection class IPX4.
Intended use
The low voltage Halogen spotlight is
intended for the illumination of gardens
or garden ponds. It is intended exclusively
for private usage, not for commercial
purposes!
Items supplied
3 Halogen spotlights
Cable
12 Colour discs
(3x red, yellow, green and blue)
Power transformer
Operating instructions
Technical data
Mains voltage: 230 V~ / 50Hz
Light bulb : 12 V, 10 W, Type MR11
Power
transformer: Spraywater protected
Protection class:II
Plug of the protection type: IP44
Lamps of the protection type: IP68