La Crosse Technology BC-900 Battery Charger User Manual


 
4
Note:
The discharging current is always set to be half of the coming charging current whose upper limit is 1000 mA (see Table 2). Therefore the user is
recommended to carefully select the discharging current so that the charging current afterward will not be too high.
The mode key shall first be pressed and held for 1 second to activate the mode change. The subsequent pressing of the mode key will toggle
between the “Charge”, “Discharge”, “Test” and “Refresh” mode.
Table 2. DISCHARGE MODE Current
User-selected
Discharging current
100 mA 250 mA 350 mA 500 mA
Thereafter Charging
current
200 mA 500 mA 700 mA
1000
mA
Finally, batteries will be fully charged in discharge mode and “Full” will be displayed. If the user presses the DISPLAY key at this time, "charge" icon
instead of "discharge" icon will be displayed.
REFRESH MODE
Old rechargeable batteries and those that have not been used for a long time require refreshing. This process will recover the optimum capacity of the
rechargeable batteries. By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode can be selected.
Refresh mode will start with discharging the rechargeable battery, then charging it. The repeated discharging and charging cycles will be launched until
no further increase in the measured capacities is estimated.
Note:
z
By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode can be selected. (The mode key shall first
be pressed and held for 1 second to activate the mode change. The subsequent pressing of the mode key will toggle between the “Charge”,
“Discharge”, “Test” and “Refresh” mode.)
Then the user may also select different discharging current by pressing the CURRENT key (see “Note” in Discharge mode and Table 2), within 8
seconds after inserting the batteries. (Or the display will blink once to indicate the end of setting and the current cannot be changed afterward.).
z
It may take up to several days to finish the refreshing process, depending on the selected discharging current.
z
The maximum refresh current is 1000 mA and is not affected by the number of rechargeable batteries inserted.
TEST MODE
In the Test mode the rechargeable batteries will first be fully charged and then discharged to determine the capacities. Finally, the rechargeable batteries
are charged up again and the capacity in (mAh) of (Ah) will be estimated and shown after the discharging ends.
By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Test mode can be selected. (The mode key shall first be
pressed and held for 1 second to activate the mode change. The subsequent pressing of the mode key will toggle between the “Charge”, “Discharge”,
“Test” and “Refresh” mode.)
Note:
z
After selecting the Test mode the user may select different charging currents in the Test mode by pressing the CURRENT key, within 8 seconds
after the batteries are inserted. The afterward-discharging current will be half of the selected charging current (see Table 3).
Table 3. TEST MODE Current
User-selected
Charging current
200 mA 500 mA 700 mA
1000
mA
Thereafter
Discharging
current
100 mA 250 mA 350 mA 500 mA
z
The maximum charging current is 1000 mA and is not affected by the number of rechargeable batteries inserted.
z
After the test mode is finished, the display will shift between the “Full” sign and the battery capacity (in mAh or Ah) automatically in 3-second
intervals until the rechargeable batteries are removed. The user can switch to other displays by pressing the DISPLAY key.
Refresh mode (the battery is
being discharged)
Discharging current: 250 mA
Test mode
The Charging
current in (mA)
Battery capacity displayed in
(mAh) as the checking is
finished in Test mode.