9
Operation
Leica Lino 757665i en
de
en
F
I
E
P
NL
DK
S
N
FIN
J
CN
ROK
PL
HR
H
RUS
CZ
GR
LT
LV
EST
SLO
SK
m
TR
Checking the accuracy of the horizontal line
(only Lino L360, L2P5, L2+, L2G+, and L2)
Place the Lock switch 3 in the "Unlocked" ( )
position.
Position the instrument approx. 5 m away from the
wall. Direct the instrument at the wall and switch on
with the LASER key 1. Activate the laser line with the
LASER key 1 and mark the intersection point of laser
crosshairs on the wall.
Swivel the instrument to the right and then to the
left. Observe the vertical deviation of the horizontal
line from the marking. If the difference does not
exceed 3 mm, then the Leica Lino is within tolerance.
Checking the accuracy of the vertical line:
(only Lino L360, L2P5, L2+, L2G+, and L2)
Place the Lock switch 3 in the "Unlocked" ( )
position.
As reference, use a plumb-bob and attach it as close
as possible to an approx. 3 m high wall.
Position the instrument at a distance of approx.
1.5 m from the wall at an elevation of approx. 1.5 m.
Direct the instrument at the wall and switch on with
the LASER key 1. Activate the laser line with the
LASER key 1. Rotate the instrument and align it with
the bottom of the plumb line. Now read off the
maximum deviation of the laser line from the top of
the plumb line. If the difference does not exceed
3 mm, then the Leica Lino is within tolerance.
max.
3 mm
5 m
1.5 m
max.
3 mm