LG Electronics 47LY340C Work Light User Manual


 
31
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
RS-232C Configurations
7-Wire Configuration
(Serial female-female NULL modem cable)
PC TV
RXD
2 3
TXD
TXD
3 2
RXD
GND
5 5
GND
DTR
4 6
DSR
DSR
6 4
DTR
RTS
7 8
CTS
CTS
8 7
RTS
D-Sub 9 D-Sub 9
3-Wire Configurations(Not standard)
PC TV
RXD
2 3
TXD
TXD
3 2
RXD
GND
5 5
GND
DTR
4 6
DSR
DSR
6 4
DTR
RTS
7 8
CTS
CTS
8 7
RTS
D-Sub 9 D-Sub 9
Set ID
Set ID number; “Real Data Mapping”
1 Press SETTINGS to access the main menus.
2 Press the Navigation buttons to scroll to
Option and press OK.
3 Press the Navigation buttons to scroll to Set
ID and press OK.
4 Scroll left or right to select a set ID number
and select CLOSE. The adjustment range is
1-99.
5 When you are finished, press EXIT.
*Real data mapping
0 : Step 0
A : Step 10 (SET ID 10)
F : Step 15 (SET ID 15)
10 : Step 16 (SET ID 16)
63 : Step 99 (SET ID 99)
64 : Step 100