Lightolier 26038W Work Light User Manual


 
ProSpec
Track Lighting 26038W
Page 2 of 2 Wall Wash Cylinder PAR38
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 (508) 679-8131 Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902
DISTANCE TO SIDE OF UNIT
6" 12" 18" 24" 30" 36" 42" 48"
0 11.0 6.5 5.5 3.0 2.0 1.5 1.0 0.5 0.5 19.5 16.5 19.5 15.0 10.5 15.0
1 70.0 65.0 34.0 12.0 5.5 8.0 1.5 1.0 1.0 97.0 109.5 97.0 80.0 48.5 80.0
2 115.0 110.0 66.0 26.0 9.0 3.5 2.0 1.0 1.0 171.0 190.5 171.0 129.0 95.0 129.0
2.5 140.0 130.0 80.0 36.0 14.0 4.5 2.5 1.5 1.0 217.0 231.0 217.0 160.0 120.0 160.0
3 120.0 115.0 77.0 39.0 16.5 6.0 2.5 1.5 1.5 203.0 217.0 203.0 144.0 120.0 144.0
4 48.0 48.0 40.0 24.0 14.0 7.5 3.0 2.0 1.5 102.0 113.0 102.5 71.0 69.0 71.0
5 17.0 17.0 16.0 11.5 8.5 5.5 3.0 2.0 1.5 46.5 51.0 46.5 33.0 32.5 33.0
6 8.0 7.0 8.0 6.0 5.0 3.5 2.8 2.0 1.5 25.5 27.0 25.5 18.5 18.5 1 8.5
7 4.0 4.0 5.0 3.5 3.0 3.0 2.0 2.0 1.0 15.0 18.5 15.0 12.0 12.5 12.0
8 2.5 3.0 3.0 2.5 2.5 2.5 2.0 1.5 0.5 11.5 14.0 11.5 9.0 0.0 9.0
10'-0" Ceiling Height Track 40" from Wall*
DISTANCE TO SIDE OF UNIT
12' 24' 36' 48" 60' 72" 84'
0 6.0 5.0 2.5 2.5 2.0 1.0 0.5 0.0 12.0 9.5 12.0 7.5 6.0 7.5
1 13.0 11.0 9.0 3.5 2-0 1.0 0.5 0.5 21.5 24.0 21.5 17.0 13.5 17.0
2 23.0 18.0 12.0 4.5 3.0 1.0 0.5 0.5 82.5 83.0 82.5 26.0 18.0 26.0
3 25.0 28.0 14.5 5.0 8.0 1.0 0.5 0.5 86.5 40.5 36.5 28.0 21.0 28.0
4 33.0 27.0 15.0 6.0 2.5 1.0 0.5 0.5 48.0 45.0 48.0 36.0 22.5 36.0
4.5 34.0 28.0 16.0 6.0 2.5 1.0 1.0 0.5 48.0 47.0 48.0 37.0 23.5 37.0
5 28.0 25.0 15.0 6.0 2.5 1.5 1.0 0.5 41.0 43.0 41.0 31.5 22.0 81.5
6 20.0 18.0 13.0 5.5 2.0 1.5 1.0 0.5 82.0 34.0 32.0 28.5 20.0 23.5
7 15.0 18.0 9.0 4.0 1.5 1.5 1.0 1.0 25.0 25.0 25.0 18.0 14.5 18.0
8 10.0 8.5 6.0 3.0 1.5 1.5 1.0 1.0 18.0 18.0 18.0 18.0 10.5 13.0
9 8.0 7.0 4.5 2.0 1.5 1.5 1.0 1.0 14.0 14.0 14.0 11.0 8.5 11.0
10 5.0 4.0 8.5 1.5 1.5 1.5 1.0 1.0 9.0 10.5 9.0 7.5 6.5 7.5
12'-0" Ceiling Height Track 66" from Wall*
DISTANCE TO SIDE OF UNIT
12' 24' 36' 48' 60' 72' 84' 96'
0 3.5 3.0 2.5 2.0 1.0 1.0 0.5 0.5 0.5 5.0 5.0 5.0 4.0 3.0 42
1 5.5 5.0 4.0 3.0 1.5 1.0 0.5 0.5 0.5 7.5 7.5 7.5 6.0 3.5 6.2
2 8.0 7.5 5.5 3.5 2.0 1.5 1.0 0.5 0.5 10.5 10.0 10.5 8.5 5.0 8.8
3 9.0 8.5 7.0 4.5 2.5 1.5 1.0 4.0 0.5 12.0 12.0 12.0 9.5 5.5 9.8
4 10.0 10.0 8.0 5.5 8.0 2.0 1.0 1.0 0.5 18.5 14.5 18.5 10.5 6.5 10.6
5 12.5 12.0 10.0 6.5 3.5 2.0 1.0 1.0 0.5 17.0 17.5 17.0 13.5 8.0 13.4
6 15.0 14.0 11.0 7.5 4.5 2.5 1.5 1.0 1.0 20.0 20.0 20.0 16.5 9.5 16.4
6.5 15.0 14.0 11.0 8.0 4.5 3.0 1.5 1.0 0.5 21.5 20.5 21.5 16.5 10.0 16.4
7 14.0 12.5 10.5 7.5 4.5 8.0 1.5 1.0 0.5 20.0 19.5 20.0 15.0 9.5 15.6
8 12.5 11.5 10.0 7.0 4.0 3.0 1.5 1.5 0.5 18.5 18.0 18.5 13.5 9.0 15.6
9 10.0 9.0 8.0 6.0 4.0 8.0 1.5 1.5 0.5 16.0 15.0 16.0 11.0 8.5 11.2
10 8.5 8.0 7.0 5.0 4.0 3.0 1.5 1.5 0.5 14.0 18.5 14.0 19.5 8.5 19.6
11 7.0 6.5 6.0 4.5 8.0 8.0 1.5 1.5 0.5 12.5 11.0 12.5 7.5 7.0 7.6
12 5.5 5.0 4.2 3.0 3.0 2.0 1.5 1.5 0.5 9.5 8.5 9.5 6.0 6.5 6.2
Lighting Data: 150W PAR38 FL
FOOTCANDLES ON WALL: Single Units Multiple Units
EXAMPLE: With track located 40" from wal and
multiple units spaced 38" on center and aimed
60° from horizontal, the illumination on wall
5' 6" from floor will be 48 f.c. beneath units and
47 f.c. between units.
38"40"
48 f.c.
47 f.c.
60
°
5'-6"
8'-0" Ceiling Height Track 22" from Wall*
Track Dist.
from Wall
Track Dist.
from Wall
*At recommended track distance from wall for
corresponding ceiling height, wall washer will
provide maximum Illumination at eye level
(5' 6' above floor) when aimed 60 from horizontal
(I.E.S. recommended practice).
Footcandles shown In table for multiple units are
based on a minimum of 5 units when on 18", 27", or
38" centers and 8 units when on 57" 62", or 98"
centers.
Footcandle values are based on average room
conditions.
Track Dist.
from Wall
Job Information Type: