Lightolier C6E17OHW Work Light User Manual


 
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Calculite
®
HID Open Downlight C6E17OHW
Page 2 of 2 6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information Type:
ANGLE 45° 90°
0 2199 2199 2199
5 2316 2307 2295
10 2239 2285 2376
15 2254 2332 2445
20 2217 2409 2409
25 1925 2146 2280
30 1631 1837 1973
35 1255 1477 1508
40 842 1004 1050
45 526 628 686
50 177 251 255
55 20 23 28
60 6 6 6
65 2 3 3
70 1 1 2
75 0 1 0
80 0 1 0
85 0 0 0
90 0 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1849 32.45 56.6
0-40 2728 47.86 83.47
0-60 3263 57.26 99.87
0-90 3268 57.34 100
40-90 540 9.48 16.53
60-90 4 0.08 0.13
90-180 0 0 0
0-180 3268 57.34 100
70W ED17 OPEN RATED PHILIPS CMH LAMP, LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE 45° 90°
45 40771 48897 53373
55 1947 2203 2684
65 291 382 337
75 73 219 73
85 0 0 0
** EFFICIENCY = 57.3% ** CERTIFIED TEST REPORT NO. 2380FR, DATE: NOV 22, 2003
SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ANGLE 45° 90°
0 3063 3063 3063
5 3152 3102 3117
10 2979 3043 3239
15 3014 3150 3364
20 3044 3348 3351
25 2675 2970 3248
30 2276 2582 2824
35 1783 2072 2163
40 1214 1447 1530
45 760 915 1005
50 271 361 397
55 24 27 42
60 3 5 6
65 1 2 1
70 0 0 0
75 0 0 0
80 0 0 0
85 0 0 0
90 0 0 0
100W ED17 OPEN RATED CMH LAMP, LUMEN RATING = 8500 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE 45° 90°
45 58940 71209 78198
55 2321 2601 4064
65 146 294 147
75000
85 0 0 0
** EFFICIENCY = 53.8% ** CERTIFIED TEST REPORT NO. 2381FR, DATE: MAR 21, 2004
SC = 1.3 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2550 30.01 55.79
0-40 3796 44.66 83.04
0-60 4569 53.76 99.95
0-90 4571 53.79 100
40-90 775 9.12 16.96
60-90 2 0.02 0.05
90-180 0 0 0
0-180 4571 53.79 100
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .64 .64 .64 .64 .63 .63 .60 .60 .57 .57 .54
1 .61 .60 .58 .57 .59 .56 .56 .55 .54 .53 .51
2 .58 .56 .54 .52 .55 .51 .53 .50 .52 .49 .47
3 .55 .52 .50 .48 .51 .47 .50 .46 .49 .46 .44
4 .53 .49 .46 .44 .48 .44 .47 .43 .46 .43 .41
5 .50 .46 .42 .40 .45 .40 .44 .40 .43 .39 .38
6 .47 .43 .39 .37 .42 .37 .41 .37 .41 .37 .36
7 .45 .40 .36 .34 .39 .34 .39 .34 .38 .34 .33
8 .42 .37 .34 .31 .36 .31 .36 .31 .35 .31 .30
9 .40 .34 .31 .29 .34 .29 .33 .28 .33 .28 .28
10 .37 .32 .28 .26 .32 .26 .31 .26 .31 .26 .25
LUMINAIRE INPUT WATTS = 110
Coefficients of Utilization
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .68 .68 .68 .68 .67 .67 .64 .64 .61 .61 .57
1 .65 .64 .62 .61 .63 .60 .60 .58 .58 .57 .54
2 .62 .60 .58 .56 .59 .55 .57 .54 .55 .53 .51
3 .59 .56 .53 .51 .55 .50 .53 .50 .52 .49 .47
4 .56 .52 .49 .47 .52 .47 .50 .46 .49 .46 .44
5 .53 .49 .45 .43 .48 .43 .47 .43 .46 .42 .41
6 .51 .46 .42 .40 .45 .40 .44 .40 .44 .39 .38
7 .48 .43 .39 .37 .42 .37 .41 .36 .41 .36 .35
8 .45 .40 .36 .34 .39 .34 .39 .34 .38 .33 .32
9 .42 .37 .33 .31 .36 .31 .36 .31 .35 .31 .30
10 .40 .34 .31 .28 .34 .28 .33 .28 .33 .28 .27
LUMINAIRE INPUT WATTS = 78
Coefficients of Utilization
1,250
1,875
625
2,500
30°
60°
1,750
2,625
875
3,500
30°
60°