Calculite
®
HID Downlight C7E17VM
Page 2 of 2 7" Aperture, ED17 (Enclosed), Ceramic Metal Halide, Medium Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information Type:
1,500
750
2,250
3,000
2,250
4,500
30°
60°
30°
60°
70W ED17 (ENCLOSED), PHILIPS COATED MH UNSHIELDED. LUMEN RATING = 6000 LMS., AROMAT CAT, CL FINISH REFLECTOR TRIM.
ANGLE MEAN CP LUMENS
0 5184
5 4618 439
10 3993
15 3481 982
20 2899
25 2453 1117
30 1843
35 1256 808
40 787
45 407 329
50 98
55 42 48
60 32
65 23 19
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2537 42.3 67.82
0-40 3345 55.76 89.41
0-60 3722 62.04 99.48
0-90 3741 62.36 100
40-90 396 6.6 10.59
60-90 19 0.33 0.52
90-180 0 0 0
0-180 3741 62.36 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 23288
55 2932
65 2213
75 0
85 0
** EFFICIENCY = 62.4% ** CERTIFIED TEST REPORT NO. 2518FR, DATE: MAR 6, 2004
SC = .7 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .73 .73 .69 .69 .66 .66 .62
1 .71 .70 .68 .67 .69 .66 .66 .64 .64 .62 .59
2 .68 .66 .64 .62 .65 .61 .63 .60 .61 .59 .56
3 .65 .62 .59 .57 .61 .57 .60 .56 .58 .55 .53
4 .63 .59 .56 .54 .58 .53 .57 .53 .56 .52 .51
5 .60 .56 .52 .50 .55 .50 .54 .49 .53 .49 .48
6 .58 .53 .49 .47 .52 .47 .51 .47 .51 .46 .45
7 .55 .50 .46 .44 .49 .44 .49 .44 .48 .43 .43
8 .52 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40
9 .50 .44 .41 .39 .44 .39 .44 .39 .43 .38 .38
10 .48 .42 .39 .36 .42 .36 .41 .36 .41 .36 .35
LUMINAIRE INPUT WATTS = 78.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W ED17 (ENCLOSED), PHILIPS COATED MH UNSHIELDED. LUMEN RATING = 9000 LMS., AROMAT, CL FINISH REFLECTOR TRIM.
ANGLE MEAN CP LUMENS
0 7771
5 6922 659
10 5985
15 5217 1471
20 4344
25 3675 1672
30 2760
35 1879 1208
40 1176
45 606 490
50 141
55 57 67
60 43
65 30 25
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3802 42.25 67.99
0-40 5010 55.68 89.6
0-60 5567 61.86 99.55
0-90 5592 62.14 100
40-90 581 6.46 10.4
60-90 25 0.28 0.45
90-180 0 0 0
0-180 5592 62.14 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 34641
55 4040
65 2833
75 0
85 0
** EFFICIENCY = 62.1% ** CERTIFIED TEST REPORT NO. 2519FR, DATE: MAR 6, 2004
SC = .7 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .71 .69 .68 .67 .68 .66 .66 .64 .63 .62 .59
2 .68 .66 .63 .62 .64 .61 .62 .60 .61 .58 .56
3 .65 .62 .59 .57 .61 .57 .60 .56 .58 .55 .53
4 .63 .59 .56 .53 .58 .53 .57 .53 .55 .52 .51
5 .60 .55 .52 .50 .55 .50 .54 .49 .53 .49 .48
6 .57 .53 .49 .47 .52 .47 .51 .47 .50 .46 .45
7 .55 .50 .46 .44 .49 .44 .48 .44 .48 .43 .42
8 .52 .47 .44 .41 .46 .41 .46 .41 .45 .41 .40
9 .50 .44 .41 .39 .44 .39 .43 .39 .43 .38 .37
10 .47 .42 .39 .36 .42 .36 .41 .36 .41 .36 .35
LUMINAIRE INPUT WATTS = 110
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
1,125
3,375