Calculite
®
HID Downlight C7E17VW
Page 2 of 2 7" Aperture, ED17 (Enclosed), Ceramic Metal halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .71 .69 .68 .66 .68 .65 .65 .63 .63 .61 .58
2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .57 .55
3 .64 .61 .58 .56 .60 .55 .58 .55 .57 .54 .52
4 .61 .57 .54 .52 .57 .51 .55 .51 .54 .50 .49
5 .59 .54 .50 .48 .53 .48 .52 .47 .51 .47 .46
6 .56 .51 .47 .45 .50 .45 .49 .44 .48 .44 .43
7 .53 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40
8 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37
9 .47 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34
10 .45 .39 .35 .33 .39 .33 .38 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 78.0
ANGLE MEAN CP LUMENS
0 3077
5 3138 298
10 3124
15 3095 861
20 2830
25 2407 1111
30 1960
35 1523 949
40 1036
45 609 461
50 130
55 7 33
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
70W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 6000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 34796
55 475
65 0
75 0
85 0
** EFFICIENCY = 61.9% ** CERTIFIED TEST REPORT NO. 2412FR, DATE: JAN 12, 2004
SC = 1.0 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2269 37.83 61.13
0-40 3218 53.64 86.69
0-60 3712 61.87 99.99
0-90 3712 61.88 100
40-90 494 8.24 13.31
60-90 0 0 0.01
90-180 0 0 0
0-180 3712 61.88 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
1,500
750
2,250
3,000
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .70 .69 .67 .66 .68 .65 .65 .63 .63 .61 .58
2 .67 .65 .63 .61 .64 .60 .62 .59 .60 .57 .55
3 .64 .61 .58 .56 .60 .55 .58 .54 .57 .54 .52
4 .61 .57 .54 .52 .57 .51 .55 .51 .54 .50 .49
5 .58 .54 .50 .48 .53 .48 .52 .47 .51 .47 .46
6 .56 .51 .47 .45 .50 .45 .49 .44 .48 .44 .43
7 .53 .47 .44 .42 .47 .41 .46 .41 .45 .41 .40
8 .50 .44 .41 .38 .44 .38 .43 .38 .43 .38 .37
9 .47 .42 .38 .35 .41 .35 .41 .35 .40 .35 .34
10 .45 .39 .35 .33 .39 .33 .38 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 110.0
ANGLE MEAN CP LUMENS
0 4614
5 4705 446
10 4685
15 4641 1291
20 4244
25 3609 1667
30 2940
35 2283 1423
40 1553
45 912 691
50 195
55 9 48
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
100W ED17 (ENCLOSED) PHILIPS CMH, LUMEN RATING = 9000 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 52135
55 639
65 0
75 0
85 0
** EFFICIENCY = 61.8% ** CERTIFIED TEST REPORT NO. 2509FR , DATE: MAR 3, 2004
SC = 1.0 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3403 37.82 61.15
0-40 4826 53.62 86.71
0-60 5565 61.84 100
0-90 5565 61.84 100
40-90 739 8.22 13.29
60-90 0 0 0
90-180 0 0 0
0-180 5565 61.84 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
2,250
1,125
3,375
4,500